Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Products
Model No.: BT06
Status: New
Applicable Industry: Energy &Amp; Mining
Out-of-warranty Service: Online Support
Where To Provide Local Services (in Which Countries Are There Overseas Service Outlets): United States, Philippines, Thailand, South Korea
Showroom Location (in Which Countries Are There Sample Rooms Overseas): Philippines, South Korea
Video Factory Inspection: Provided
Mechanical Test Report: Provided
Marketing Type: New Product 2020
Core Component Warranty Period: 1 Year
Old And New: New
Species: Natural Circulation
Use: Power Station
Structure: Fire Tube
Pressure: High Pressure
Types Of: Horizontal
Fuel: Oil-Fired
Place Of Origin: China
Output: Hot Water
Warranty Period: 1 Year
Core Selling Point: Long Service Life
Packaging: Bundle packing/ wooden case
Productivity: 2000ton/month
Transportation: Ocean
Place of Origin: China
Supply Ability: 2000ton/month
Certificate: ISO,BV,TUV,SGS
HS Code: 73043190
Port: Shanghai
Payment Type: L/C,T/T
Incoterm: FOB,CFR,CIF,EXW
ASTM A210 —American Society for Testing and Materials Standards
ASME SA210 — AmericanSociety of Mechanical Engineers standards
Purpose:
For boiler pipesand boiler flue pipe, including security side, the dome and the support tubeand superheater tubes minimum wall thickness of seamless carbon steel pipes.
The mainproduction steel grades:
A-1, C, etc. arenegotiated, but also supply other grades of steel.
Mechanicalproperties:
Standard | Grade | Tensile strength (MPa) | Yield strength (MPa) | Elongation (%) |
ASTMA210 ASME SA210 | A-1 | ≥415 | ≥255 | ≥30 |
C | ≥485 | ≥275 | ≥30 |
Chemical composition:
Standard | Grade | Chemical Composition | |||||||||
C | Si | Mn | P | S | Cr | Mo | Cu | Ni | V | ||
ASTM A210 ASME SA210 | C | ≤0.35 | ≥0.10 | 0.29~1.06 | ≤0.035 | ≤0.035 | / | / | / | / | / |
A-1 | ≤0.27 | ≥0.10 | ≤0.93 | ≤ 0.035 | ≤0.035 | / | / | / | / | / |
Hot-finished tubes need not be heat treated. Cold-finished tubes shall be given a subcritical anneal, a full anneal, or a normalizing heat treatment after the final cold-finishing process.
The tubes shall have a hardness not exceeding the following: 79 HRB or 143 HRB for Grade A-1,89 HRB or 179 HRB for Grade C.
Hydrostatic or Nondestructive Electric Test —Each tube shall be subjected to the hydrostatic, or,
instead of this test, a nondestructive electric test may be used when specified by the purchaser
In addition to the marking prescribed in Specifi-cation A 450/A 450M, the marking shall indicate
whether the tube is hot-finished or cold-finished.
Product Categories : Heat Exchange And Energy Transfer Tubes > SMLS Cold Drawn Tubes For Heat Exchanger And Boiler
Home > Products > Heat Exchange And Energy Transfer Tubes > SMLS Cold Drawn Tubes For Heat Exchanger And Boiler > ASTM A210 SEAMLESS MEDIUM-CARBON STEEL BOILER AND SUPERHEATER TUBES
Send Inquiry
Mr. Gary
Email:
Send Inquiry Tel:+86-512-58577588
Fax:
Mobile Phone:+8613915729750
Email:
Address:Yinhe Massion,Zhangjiagang City,Jiangsu Province, Suzhou, Jiangsu
Related Products List
Mobile Site
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.